Conductivity-meter

Conductivity-meter CSD22

  • conductivity range: 200 uS, 2000 uS, 20 mS, 200 mS
  • cell coefficient adjustment
  • input: BNC
  • output: 0-5 V standard (4-20 mA or 0-2 v in option)
  • adaptater 220 V / 9 V included
  • dimensions: 106 x 187 x 54 mm


Conductimeter CPD37

  • portable
  • calibration with buttons


Heitomat

Heitomat conductivity

  • industrial devices with microprocessor and temperature measurement and automatic compensation
  • IP65 box or box to insert available
  • 2 alarms and 2 analog outputs (4 - 20 mA)
  • option RS232 for the conductivity-meter
  • Conductivity-meter range: 0-2 uS, 0-20 uS, 0-200 uS, 0-2 mS, 0-20 mS, 0-200 mS


Conductivity-meter CM200

  • 5 ranges from 0-2 uS to 0-20 mS
  • IP65
  • manual calibration
  • options: threshold with led and relay, 4-20 mA output

Chlorine-meter CLM200

  • activ chlorine, free chlorine
  • range: from 0 to 20 mg/l (ppm)
  • IP65
  • manual calibration
  • options: threshold with led and relay, 4-20 mA output


Blind transmitter with 4-20 mA output (conductivity, chlorine)

  • power supply through the 4-20 mA current loop
  • calibration has to be made on the master
  • IP65
  • dimensions: 110 mm x 75 mm x 60 mm


MicroDirect Conductivity

This device is waterproof and dust-tight (IP67) unit conductivity. The compact, robust housing and the electrode replacement option meet the high standards required of state-of-the-art technology.

All units are equipped with an automatic switch-off and a "Hold" function which "freezes" the result in the display with a single keypress.

Operation temperature: 0-50 °C

Battery capacity: > 150 h

MicroDirect Conductivity EC 11

  • range: 0 to 2000 µS/cm, 0 to 20 mS/cm
  • resolution: 10 µS/cm
  • accuracy: 1% FS
  • calibration: 1412 µS/cm or 12.88 mS/cm
  • with temperature compensation

MicroDirect TDS 11

  • range: 0 to 2000 ppm (parts per million), 0 to 10.00 ppt (parts per thousand)
  • resolution: 10 ppm, 0.10 ppt
  • accuracy: 0.1% FS
  • calibration: 9.98 ppm, 9.02 ppt
  • with temperature compensation

MicroDirect Salinity 11

  • range: 0 to 10,00 ppt (parts per thousand) NaCl
  • resolution: 0.1 ppt
  • accuracy: 0.1% FS
  • calibration: yes
  • with temperature compensation


Conductivity-meter SensoDirect 110

SensoDirect Con110

  • range: 0.001 to 1.999 mS/cm, 0.01 to 19.99 ms/cm
  • resolution: 0.001 and 0.01 mS/cm
  • temperature compensation: 0 - 100 °C, automatically 2%/K, 25 °C
  • accuracy: ± 3 % Full Scale ± 1 Digit (23 ± 5 °C)
  • ambient conditions: 0 to 50 °C, 0 to 80 % humidity (non condensing)
  • battery: 9 V-power
  • dimensions: 208 x 110 x 34 mm (L x W x H)
  • the conductivity probe is included

SensoDirect Salt110

  • range: 0 to10% Salt
  • resolution: 0.01% Salt
  • temperature compensation: 0-50°C, automatically
  • accuracy: ± 0.5% (23 ± 5°C)
  • ambient conditions: 0 to 50 °C, 0 to 80 % rel. humidity (non condensing)
  • battery: 9 V-power block
  • dimensions: 208 x 110 x 34 mm (L x W x H)
  • the probe is included


Conductivity-meter SensoDirect CON200

  • conductivity range: 0.0 to 200.0 µS/cm, 0 to 2000 µS/cm, 0.00 to 20.00 mS/cm, 0.0 to 200.0 mS/cm
  • resistance: 0.005 to 100.0 kOhm*cm
  • TDS: 0 to 1999 mg/l
  • salinity: 0.0 to 70.0 g/kg
  • accuracy: ± 0.5 % v. MW ± 0.5 % FS (± 3 digits)
  • temperature: -5.0 to 100.0 °C
  • accuracy: ±0.3K
  • cell constant: 0.50 ± 0.10 cm-1
  • temperature compensation selectable: linear (0.3 to 3.0 %/K), non-linear in acc. with EN 27 888, no compensation
  • reference temperature: 20 °C and 25 °C
  • calibration: 1-point calibration in the range 1000 to 2000 µS/cm
  • nominal temperature: 25°C
  • operating temperature: Unit: 0 to + 50 °C; Measuring cell: -5 to 80 °C (up to 100 °C for short periods)
  • power supply: 4 x 1.5 V battery, Type AA Operating time up to 3000 h
  • power consumption: ca. 3 mA
  • automatic-Off function: 0 - 120 minutes
  • measuring cell: 4-pole conductivity measuring cell with integrated temperature-sensor (NTC10kOhm). Electrode material: special graphite Shaft material: epoxy Temperature sensor: stainless steel Dimensions: diameter 12 mm, 120 mm long
  • dimensions: 175 x 140 x 45 mm (L x W x H)


BAMOPHAR 364 conductivity meter for inductive probe

Combined with the TCS 3020 or TCS S50 inductive probe, the BAMOPHAR 364 continuously measures the conductivity of the liquid over a range of 0 to 2000 mS / cm throughout the various treatment processes.

The TCS 3020 NORYL probe is recommended for applications with neutral liquids. The TCS S50 PEEK probe is suitable for applications requiring high chemical or temperature resistance.

Applications: cooling tower monitoring, brine concentration control, clean water control (well outlet, drinking water systems, hot springs, etc.), rainwater control, monitoring at the outlet of water treatment area, acid and base concentration measurement, chemical quality monitoring.

  • Color Touch Screen
  • Measuring ranges: 0 - 2 mS/cm to 0 - 2000 mS / cm
  • Automatic temperature compensation
  • 2 Analog Outputs 0/4-20 mA
  • 3 independent relays
  • 1 Alarm relay
  • Options: RS 422 / J-BUS + LOGGER
  • Extension possible for 2nd measurement input


You will find here the conductivity probes
Contact

Top

Sysmatec
Oberdorfstrasse 51
CH 3930 Eyholz
tel + 41 27 946 80 18
fax + 41 27 946 86 42
info@sysmatec.ch