Sysmatec

Temperature / humidity data loggers and chart recorders

TK500

Data logger TK500

  • temperature range: -20°C to +70°C
  • humidity range: 0 to 95 % RH, no-condensing
  • in the box integrated sensors
  • temperature precision: ±1 °C
  • humidity precision: ±2 % between 10 % and 90 % RH
  • respons time: 10 minutes for 63 % of the full scale
  • memory: 7936 points (3,968 per channel)
  • sample interval: 10 seconds to 24 hours in 10 seconds increments
  • download time: about 30 seconds, RS232 interface
  • ambient operating conditions: -20 to 70°C, 0 to 95 % RH non-condensing
  • 3 V lithium battery included
  • battery life (average): 1 year
  • weight 12,4 g
  • software for data transfert: ref. A015
  • 21CFR11 software for data transfert, ref. A025


TK550

Data logger TK550

  • temperature range: -20°C to +70°C
  • humidity range: 0 to 95 % RH, no-condensing
  • in the box integrated sensors
  • temperature precision: ±1 °C
  • humidity precision: ±2 % between 10 % and 90 % RH
  • respons time: 10 minutes for 63 % of the full scale
  • memory: 7936 points (3,968 per channel)
  • sample interval: 10 seconds to 24 hours in 10 seconds increments
  • download time: about 30 seconds, USB interface
  • ambient operating conditions: -20 to 70°C, 0 to 95 % RH non-condensing
  • 3 V lithium battery included
  • battery life (average): 1 year
  • weight 23 g
  • software for data transfert: ref. A016 and SW400 for calibration
  • 21CFR11 software for data transfert, ref. A026


Data logger TP425

  • temperature range: -20 to +70 °C
  • humidity range: 0 to 95 % RH, no-condensing
  • in the box integrated sensors
  • Start/Stop button
  • temperature precision: ±0,5 °C between -6 °C and +48 °C, ± 1 °C outside of this intervall
  • humidity precision: ± 2 % from 0% to 60 % RH, ± 3 % from 60% to 95 %
  • memory: 32000 points
  • sample interval: 10 seconds to 24 hours in 10 seconds increments
  • download time: about 30 seconds
  • ambient operating conditions: -20 to 70°C, 0 to 95 % RH non-condensing
  • 3 V lithium battery included
  • battery life (average): 1 year
  • weight 120 g
  • software for data transfert: ref. A016 (USB) and SW400 for the calibration
  • 21CFR11 software for data transfert, ref. A026


Data logger TP125

  • temperature range: -23 to +80 °C
  • humidity range: 0 to 95 % RH, no-condensing
  • in the box integrated sensors
  • temperature precision: ±0,5 °C between -17 °C and +70 °C, ± 1 °C outside of this intervall
  • humidity precision: ±2 % at 40 % and 23 °C
  • memory: 32000 points
  • sample interval: 10 seconds to 24 hours in 10 seconds increments
  • download time: about 30 seconds
  • ambient operating conditions: -40 to 80°C, 0 to 95 % RH non-condensing
  • Alarm: LED - Flashes Red when High/Low Limits are met
  • 3 V lithium battery included
  • battery life (average): 1 year
  • weight 53 g
  • software for data transfert: ref. A016 (USB)
  • 21CFR11 software for data transfert, ref. A026


Data logger TM320/TM325/TM725

TM320 specific description

  • temperature range: -20 °C to +70 °C
  • humidity range: 0 to 95 % RH, no-condensing
  • temperature precision: ±0,5 °C
  • humidity precision: ±2 % at 25 °C
  • dew point range (calculated): -30 °C to 50 °C
  • précision du point de rosée: ±2 °C de 30 à 95% RH
  • respons time: 2.5 minutes

TM325 specific description

  • external sensor
  • temperature range: -40 °C à +85 °C
  • humidity range: 0 to 95 % RH, no-condensing
  • temperature precision: ±0,5 °C
  • humidity precision: ±2 % at 25 °C
  • dew point range (calculated): -30 °C to 50 °C
  • dew point range precision: ±2 °C de 30 à 95% RH
  • respons time: 1 minutes for 63 % of the full scale

TM725 specific description

  • like the TM325 with ethernet connection
  • download time with ethernet: 2 minutes

commun description

  • display minimal and maximal temperature
  • alarme
  • memory: 32000 points (16000 for each channel for logger with 2 channels)
  • sample interval: 1 seconds to 24 hours in 1 or 10 seconds increments
  • data download with RS232, USB or memory card
  • download time: about 1.5 minutes with RS232 or 30 seconds with USB
  • ambient operating conditions: -20 to 70°C, 0 to 95 % RH non-condensing
  • for AA battery included or adapter 220 V/9 V
  • battery life (average): 6 months
  • software for data transfert, ref. A025 (RS232) or A026 (USB)
  • SW400 for calibration: TM320/TM325/TM725
  • optional software A029 for TM725
  • 21CFR11 software for data transfert, ref. A025 (RS232) or ref. A026 (USB)


Data logger EL-USB-2

  • Measurement Range: 0 to +100%RH , -35 to +80°C
  • Dew point indication via Windows Control Software
  • USB Interface
  • Memory: 16382 relative humidity and 16382 temperature
  • User-Programmable Alarm Thresholds for %RH & T
  • Status Indication via Red and Green LEDs
  • Supplied with Replaceable Internal Lithium Battery and Windows Control Software
  • Environmental Protection to IP67


FH520

Data logger FH520

  • temperature range: -17 to +50°C
  • humidity range: 0 à 95 % RH, no-condensing
  • temperature precision: ±1 °C
  • humidity precision: ±2% from 0 to 60%, ±3% from 60 to 95%
  • Alarm (Sound + Text)
  • memory: 32000 points/channel
  • recording intervall: 1 Hour, 8 Hours, 1 Day, 3 Days, 7 Days, or Custom (up to 10 Sec)
  • ambient operating conditions: -18 to 50°C, 0 to 95 % RH non-condensing
  • adapter 230 V/9 V
  • backup with 9 V battery
  • battery life (average): 2 weeks
  • display: 15 x 11 cm, touchscreen, multiple screen views, on-screen zoom and scroll
  • weight: 600 g
  • download Type: USB (1:15 minutes) or FLASH Memory Card (36 seconds)
  • software for data transfert: ref. A016 and SW400 for the calibration
  • 21CFR11 software for data transfert, ref. A026


FH525

Data logger FH525, FH535

  • like the FH520 with external probe
  • cable length: about 2 m
  • temperature range: -40 to +80°C
  • FH535: external probe +1 alarm relay


Recorder TH6

TH621 specific description

  • temperature range: 0 to +50°C
  • humidity range: 10 to 95 % RH
  • without digital display

TH622 specific description

  • temperature range: 0 to +50°C
  • humidity range: 10 to 95 % RH
  • display for the values

TH623 specific description

  • temperature range: 0 to 50°C, 0 to 85°C (selectable)
  • humidity range: 0 to 95 % RH
  • display for the values
  • alarm
  • external probe

TH625 specific description

  • temperature range: 0 to 50°C, 0 to 85°C (selectable)
  • humidity range: 0 to 95 % RH
  • display for the values
  • alarm with contact relay
  • external probe

commun description

  • temperature precision: ±0,5% for the full scale and ±1°C
  • humidity precision: ±2% from 10 to 60%, ±3% from 60 to 95%
  • respons time: 2.5 minutes
  • recording time: 24 hours or 7 days selectable
  • ambient operating conditions: 0 to 50°C, 0 to 95 % RH non-condensing
  • adapter 220V/9V
  • backup with battery
  • battery life (average): 24 hours
  • disc diameter: about 15 cm


Recorder TH8

TH800 specific description

  • temperature range: 0 to +50°C
  • temperature sensor: thermistor
  • humidity range: 10 to 95 % RH, non condensing
  • recording time: 24 hours or 7 days selectable
  • only wit batteries (4 x AA)
  • batteries life: 1 week to 12 months depending on the rotation speed

TH801 specific description

  • temperature range: 0 to +50°C
  • temperature sensor: thermistor
  • humidity range: 10 to 95 % RH, non condensing
  • recording time: 24 hours or 7 days selectable

TH802 specific description

  • temperature range: 0 to +50°C, 5 to +40 °C
  • temperature sensor: thermistor
  • humidity range: 10 to 95 % RH
  • display for the values
  • recording time: 24 hours, 7 days or 31 days selectable

TH803 specific description

  • temperature range: -20 to 50°C, 5 to +40°C (selectable)
  • temperature sensor: thermistor, remote probe
  • humidity range: 0 to 95 % RH, remote probe
  • display for the values
  • audio/ visual alarm
  • recording time: 24 hours, 7 days or 31 days selectable

general description

  • temperature precision: ±1°C
  • humidity precision: ±2% from 0 to 60%, ±3% from 60 to 95%
  • dew point range (calculated): -30 °C to 50 °C
  • dew point accuracy (calculated): ±4 °C from 10 to 95% RH
  • respons time: 2 minutes for 63 % of the full scale
  • ambient operating conditions: 0 to 50°C, 0 to 95 % RH non-condensing
  • adapter 220V/9V
  • backup with battery
  • battery life (average): 24 hours
  • disc diameter: about 24 cm


Datalogger Testo 177-H1

  • Temperature range: -20 to +70 °C (internal sensor), -40 to +120 °C (external Sensor)
  • Precision: ±0.2 °C (-25 bis +70 °C)
  • Resolution: 0.1 °C
  • Humidity range: 0 to 100 % rH (capacitiv sensor)
  • Resolution: 0.1 % rH
  • 4 Channels
  • Memory: 48000 poins
  • ambient operating conditions: -20 to +70 °C
  • Battery: Lithium-Batterie
  • Weight 130 g
  • Dimension: 103 x 64 x 33 mm


Data logger TR-72W

  • Incorporate an Ethernet/ LAN interface
  • Can be connected to wired or wireless LAN
  • One external temperature sensor (with the humidity sensor): 0 to 50 °C
  • One external humidity sensor: 10 to 95 % rH
  • Measurement Accuracy: ±0.3°C(-20 to 80°C), 5 % rH
  • Measurement Resolution Display: 0.1°C, 1 % rH
  • Recording Interval 1,2,5,10,15,20,30 seconds,1,2,5,10,15,20,30,60 minutes
  • Recording Capacity: 8,000 Readings x 2 Channels
  • Recording Method Endless (Overwrite from the oldest data when recording capacity is full), One time Method (Stop recording when recording capacity is full)
  • Power Source: Special AC Adaptor ( DC5V )
  • Data Back-up: Saved for about 3 months with 1 lithium battery (CR-2032)
  • Interface Wired LAN: 10 / 100 Base - TX RJ45 connector
  • Wireless LAN:IEEE802.11b CF type Wireless LAN Card
  • Dimentions: H55mm x W78mm x D39mm
  • Weight 101g ( Including one battery )
  • Browser Functions View Temperature and Humidity Data in Graph Form , Start Recording, Download Data , Monitor Current Readings , Check Back-up Battery
  • Warning Mail Function E-mail: Register up to 5 addresses to receive mail
  • Power Consumption: About 290mA ( when using wired LAN )
  • Security Access Controlled IP Address , ID Password Authentication
  • Working Environment for Main Unit Temperature : 0 to 50°C Humidity : 20 to 80%RH (without condensation)


MSR145S

Data logger MSR145

  • The MSR 145 is a miniaturised universal datalogger for measuring and recording different physical measurement parameters. It contains a temperature sensor, a humidity sensor with integrated temperature, a pressure sensor and a 3-axis accelerometer (X, Y and Z axes).
  • Temperature range: -20 °C to +60 °C
  • Humidity range: 0-100 % relative humidity
  • Pressure: 0 to 2000 mbar absolute (optional: to 14 000 mbar absolute)
  • Acceleration: ±10 g / ±2 g (switchable)
  • Light: 0-65 000 Lux
  • standard signal: 0 to 20 mA, 4 to 20 mA, 0 to 3.0 V, 0.5 to 4.5 V, 0 to 5.0 V, 1.0 to 6.0 V, 0 to 10.0 V, 0 to 12.0 V, 0 to 24.0 V
  • Accuracy: ±0,5 °C max. (at -10 °C to +60 °C), optional ±0,2 °C max. (at 20 °C to 40 °C), < ±2 % relative humidity (at 10-90 % relative humidity, 0 °C to 40 °C), ±2,5 mbar max. (at 750-1100 mbar absolute), Acceleration: ±0,15 g (at 25 °C)
  • Memory: 2 000 000 values, 1 000 000 000 values with an optional SD memory card
  • Data storage rate:
    • for temperature: 1 /s, every 10 s, every 30 s, every 60 s
    • for humidity: 1 /s, every 10 s, every 30 s, every 60 s
    • for pressure: 20 /s, 10 /s, 2 /s, 1 /s, every 10 s, every 30 s, every 60 s
    • for acceleration: 20 /s, 10 /s, 1 /s, every 2 s, every 5 s, every 10 s, every 30 s, every 60 s
  • Power supply: Rechargeable lithium polymer battery 188 mAh, the battery is charged via the USB connection, one battery charge is sufficient for operation of the unit for several months (measurement rate 1/minute).
  • MSR145 S: for air, size 18 x 14 x 52 mm, weight approx. 13 g, sheath material PVC, IP60
  • MSR145SW, MS145W: for air and water, size 18 x 14 x 60 mm, weight approx. 18 g, sheath material Silicon or plycarbonate, IP67
  • Data transfert: with USB connection, software is included
  • Different versions with only a few parameters (like temperature and humidity) are also available


Data logger MSR165

  • The MSR 165 is a miniaturised universal datalogger for measuring and recording different physical measurement parameters. It contains a temperature sensor, a humidity sensor with integrated temperature, a pressure sensor , a 3-axis accelerometer (X, Y and Z axes) and light
  • Temperature range: -20 °C to +60 °C
  • Humidity range: 0-100 % relative humidity
  • Pressure: 0 to 2000 mbar absolute
  • Acceleration: ±15 g
  • Light: 0 to 300 Lux, max. sensibility at 580 nm
  • Accuracy: ±0,5 °C max. (at -10 °C to +60 °C), optional ±0,2 °C max. (at 20 °C to 40 °C), < ±2 % relative humidity (at 10-90 % relative humidity, 0 °C to 40 °C), ±2,5 mbar max. (at 750-1100 mbar absolute), Acceleration: ±0,15 g (at 25 °C)
  • Memory: 2 000 000 Values
  • Data storage rate:
    • for temperature: 1 /s, every 10 s, every 30 s, every 60 s
    • for humidity: 1 /s, every 10 s, every 30 s, every 60 s
    • for pressure: 20 /s, 10 /s, 2 /s, 1 /s, every 10 s, every 30 s, every 60 s
    • for acceleration: 20 /s, 10 /s, 1 /s, every 2 s, every 5 s, every 10 s, every 30 s, every 60 s
  • Power supply: Rechargeable lithium polymer battery 900 mAh, the battery is charged via the USB connection, one battery charge is sufficient for operation of the unit for several months (measurement rate 1/second).
  • for air and water, size 39 x 23 x 72 mm, weight approx. 64 g, sheath material polycarbonate, IP67 (IP60 with the microSD card slot)
  • Data transfert: with USB connection, software is included
  • Different versions with only a few parameters (like temperature and humidity) are also available


Description

Temperature/humidity wireless data logger Newsteo (external sensor)

The logger can transfer the data directly on a monitoring computer by radio frequencies (monitoring mode) or can store the data in its memory (recording mode).

Up to 500 loggers can communicate with one RF-USB stick connected to the computer.

specification

  • external sensor
  • temperature range: -40 to 85 °C depending on the sensor
  • humidity range: 0 to 100 % RH
  • sample interval: 1 second to 4 hours
  • memory: 32768 points
  • min/max value
  • Lithium Thionyle battery, 1/2 AA or AA depending on ther version
  • battery life: 2 years (for 1 mesurement/10 minutes)
  • IP54
  • dimension: 96 mm x 40 mm x 20 mm (antenna: 90 mm)
  • RF range: 30 m to 1 km (there are different antenna sizes)
  • frequency: ISM 868 MHz (Europe); 915 MHz (USA)
  • possibility to start the recording with a magnet

applications

  • storage control
  • transport of fresh, frozen food, pharmaceuticals...
Ref. temperature range (°C) RH range (%) box signal range (m) antennea
LOG20 -40°C to +70°C +/- 0.5°C 0 to 100 % +/- 4.5 % IP54 800 external, 1/4 wave
LOG22 -40°C to +70°C +/- 0.4°C 0 to 100 % +/- 3 % IP54 800 external, 1/4 wave
LOG25 -40°C to +70°C +/- 0.3°C 0 to 100 % +/-2 % IP54 800 external, 1/4 wave


Temperature/humidity wireless data logger Newsteo (internal sensor)

The logger can transfer the data directly on a monitoring computer by radio frequencies (monitoring mode) or can store the data in its memory (recording mode).

Up to 500 loggers can communicate with one RF-USB stick connected to the computer.

specification

  • internal sensor
  • temperature range: -40 to 60 °C
  • humidity range: 0 to 100 % RH
  • sample interval: 1 second to 4 hours
  • memory: 32768 points
  • min/max value
  • Lithium Thionyle battery, 1/2 AA or AA depending on ther version
  • battery life: 2 years (for 1 mesurement/10 minutes)
  • IP54
  • dimension: 96 mm x 40 mm x 20 mm (antenna: 90 mm)
  • RF range: 30 m to 1 km (there are different antenna sizes)
  • frequency: ISM 868 MHz (Europe); 915 MHz (USA)
  • possibility to start the recording with a magnet

applications

  • storage control
  • transport of fresh, frozen food, pharmaceuticals...
Ref. temperature range (°C) RH range (%) box signal range. (m) antenn1
LGR52 -40°C to +85°C +/- 0.4°C 0 to 100 % +/- 3 % IP65 900 external, 1/2 wave
LGR55 -40°C to +85°C +/- 0.2°C 0 to 100 % +/- 2 % IP65 900 external, 1/2 wave


Wireless data logger Newsteo Tracker

The logger can transfer the data directly on a monitoring computer by radio frequencies (monitoring mode) or can store the data in its memory (recording mode). The parameters are temperature, humidity, acceleration, shock, light

Up to 500 loggers can communicate with one RF-USB stick connected to the computer.

specification

  • internal sensor
  • temperature range: -10 to +60°C +/- 0.4°C at 25°C
  • humidity range: 0 to 100 % RH ± 3% (de 20 at 80% RH)
  • light: 0 to 220 Lux +/- 30 Lux
  • acceleration: 3 axiss, - 6g to +6g +/- 0,1g
  • Free-fall height: 1 cm to 20 m +/- 5 cm
  • sample interval: 1 second to 4 hours
  • memory: 32768 points
  • min/max value
  • Lithium Thionyle battery, 1/2 AA or AA depending on ther version
  • battery life: 2 years (for 1 mesurement/10 minutes)
  • IP54
  • dimension: 96 mm x 40 mm x 20 mm (antenna: 90 mm)
  • RF range: 30 m to 1 km (there are different antenna sizes)
  • frequency: ISM 868 MHz (Europe); 915 MHz (USA)
  • possibility to start the recording with a magnet

applications

  • storage control
  • transport of fresh, frozen food, pharmaceuticals...
Ref. temperature range (°C) RH range(%) box max. signal range(m) antenna
TRK31 -10 to +60°C +/- 0.4°C 0 to 100 % +/- 3 % IP54 40 internal
TRK33 -40°C to +85°C +/- 0.4°C 0 to 100 % +/- 3 % IP54 40 internal
TRK41 -10 to +60°C +/- 0.4°C 0 to 100 % +/- 3 % IP54 800 external,1/4 Wave


Newsteo Builder for measurement of the humidity and shrinkage of concrete

It is directly buried (antenna included) into the concrete and it records the corresponding measurements in its non-erasable embedded memory (which can be at any time read by a PC).

It can also transmit them in real time, without any wire, to a PC. As all the measurements are dated, the user gets the complete history of the supervised concrete.

Two versions of the Newsteo Builder, with or without the shrinkage sensor, are available.

Spécicifications:

  • temperature range: -20°C to +124°C
  • humidity range: 0 to 100%
  • shrinkage range: -300 to 800 µm/m
  • working temperature: -20°C to +80°C
  • autonomy: 3 to 7 ans with lithium battery (depending on the measurement frequency and the working temperature)
  • measurements frequency: every 10 minutes to every 4 hours
  • storage capacity: 32768 dated values
  • protection: IP 68 (resistant to dust, to liquid concrete, suitable for continuous immersion in water under static pressure of 6 bar)
  • dimensions : 67 mm x 73 mm x 29 mm.
  • casing in tear-proof and unbreakable polyurethane
  • Shrinkage sensor dimensions: 155 mm x 20 mm x 15 mm, connection cable : 40 cm


Contact

Top

Sysmatec
Oberdorfstrasse 51
CH 3930 Eyholz
tel + 41 27 946 80 18
fax + 41 27 946 86 42
info@sysmatec.ch