TK500
|
Data logger TK500
- temperature range: -20°C to +70°C
- humidity range: 0 to 95 % RH, no-condensing
- in the box integrated sensors
- temperature precision: ±1 °C
- humidity precision: ±2 % between 10 % and 90 % RH
- respons time: 10 minutes for 63 % of the full scale
- memory: 7936 points (3,968 per channel)
- sample interval: 10 seconds to 24 hours in 10 seconds increments
- download time: about 30 seconds, RS232 interface
- ambient operating conditions: -20 to 70°C, 0 to 95 % RH non-condensing
- 3 V lithium battery included
- battery life (average): 1 year
- weight 12,4 g
- software for data transfert: ref. A015
- 21CFR11 software for data transfert, ref. A025
|
TK550
|
Data logger TK550
- temperature range: -20°C to +70°C
- humidity range: 0 to 95 % RH, no-condensing
- in the box integrated sensors
- temperature precision: ±1 °C
- humidity precision: ±2 % between 10 % and 90 % RH
- respons time: 10 minutes for 63 % of the full scale
- memory: 7936 points (3,968 per channel)
- sample interval: 10 seconds to 24 hours in 10 seconds increments
- download time: about 30 seconds, USB interface
- ambient operating conditions: -20 to 70°C, 0 to 95 % RH non-condensing
- 3 V lithium battery included
- battery life (average): 1 year
- weight 23 g
- software for data transfert: ref. A016 and SW400 for calibration
- 21CFR11 software for data transfert, ref. A026
|
 |
Data logger TP425
- temperature range: -20 to +70 °C
- humidity range: 0 to 95 % RH, no-condensing
- in the box integrated sensors
- Start/Stop button
- temperature precision: ±0,5 °C between -6 °C and +48 °C, ± 1 °C outside of this intervall
- humidity precision: ± 2 % from 0% to 60 % RH, ± 3 % from 60% to 95 %
- memory: 32000 points
- sample interval: 10 seconds to 24 hours in 10 seconds increments
- download time: about 30 seconds
- ambient operating conditions: -20 to 70°C, 0 to 95 % RH non-condensing
- 3 V lithium battery included
- battery life (average): 1 year
- weight 120 g
- software for data transfert: ref. A016 (USB) and SW400 for the calibration
- 21CFR11 software for data transfert, ref. A026
|
 |
Data logger TP125
- temperature range: -23 to +80 °C
- humidity range: 0 to 95 % RH, no-condensing
- in the box integrated sensors
- temperature precision: ±0,5 °C between -17 °C and +70 °C, ± 1 °C outside of this intervall
- humidity precision: ±2 % at 40 % and 23 °C
- memory: 32000 points
- sample interval: 10 seconds to 24 hours in 10 seconds increments
- download time: about 30 seconds
- ambient operating conditions: -40 to 80°C, 0 to 95 % RH non-condensing
- Alarm: LED - Flashes Red when High/Low Limits are met
- 3 V lithium battery included
- battery life (average): 1 year
- weight 53 g
- software for data transfert: ref. A016 (USB)
- 21CFR11 software for data transfert, ref. A026
|

|
Data logger TM320/TM325/TM725
TM320 specific description
- temperature range: -20 °C to +70 °C
- humidity range: 0 to 95 % RH, no-condensing
- temperature precision: ±0,5 °C
- humidity precision: ±2 % at 25 °C
- dew point range (calculated): -30 °C to 50 °C
- précision du point de rosée: ±2 °C de 30 à 95% RH
- respons time: 2.5 minutes
TM325 specific description
- external sensor
- temperature range: -40 °C à +85 °C
- humidity range: 0 to 95 % RH, no-condensing
- temperature precision: ±0,5 °C
- humidity precision: ±2 % at 25 °C
- dew point range (calculated): -30 °C to 50 °C
- précision du point de rosée: ±2 °C de 30 à 95% RH
- respons time: 1 minutes for 63 % of the full scale
TM725 specific description
- like the TM325 with ethernet connection
- download time with ethernet: 2 minutes
commun description
- display minimal and maximal temperature
- alarme
- memory: 32000 points (16000 for each channel for logger with 2 channels)
- sample interval: 1 seconds to 24 hours in 1 or 10 seconds increments
- data download with RS232, USB or memory card
- download time: about 1.5 minutes with RS232 or 30 seconds with USB
- ambient operating conditions: -20 to 70°C, 0 to 95 % RH non-condensing
- for AA battery included or adapter 220 V/9 V
- battery life (average): 6 months
- software for data transfert, ref. A025 (RS232) or A026 (USB)
- SW400 for calibration: TM320/TM325/TM725
- optional software A029 for TM725
- 21CFR11 software for data transfert, ref. A025 (RS232) or ref. A026 (USB)
|
 |
Data logger EL-USB-2
- Measurement Range: 0 to +100%RH , -35 to +80°C
- Dew point indication via Windows Control Software
- USB Interface
- Memory: 16382 relative humidity and 16382 temperature
- User-Programmable Alarm Thresholds for %RH & T
- Status Indication via Red and Green LEDs
- Supplied with Replaceable Internal Lithium Battery and Windows Control Software
- Environmental Protection to IP67
|
|

FH520
|
Data logger FH520
- temperature range: -17 to +50°C
- humidity range: 0 à 95 % RH, no-condensing
- temperature precision: ±1 °C
- humidity precision: ±2% from 0 to 60%, ±3% from 60 to 95%
- memory: 32000 points/channel
- recording intervall: 1 Hour, 8 Hours, 1 Day, 3 Days, 7 Days, or Custom (up to 10 Sec)
- ambient operating conditions: -18 to 50°C, 0 to 95 % RH non-condensing
- adapter 230 V/9 V
- backup with 9 V battery
- battery life (average): 2 weeks
- display: 15 x 11 cm, touchscreen, multiple screen views, on-screen zoom and scroll
- weight: 600 g
- download Type: USB (1:15 minutes) or FLASH Memory Card (36 seconds)
- software for data transfert: ref. A016 and SW400 for the calibration
- 21CFR11 software for data transfert, ref. A026
|
|

FH525
|
Data logger FH525, FH535
- like the FH520 with external probe
- cable length: about 2 m
- temperature range: -40 to +80°C
- FH535: external probe +1 alarm relay
|
|



|
Recorder TH6
TH621 specific description
- temperature range: 0 to +50°C
- humidity range: 10 to 95 % RH
- without digital display
TH622 specific description
- temperature range: 0 to +50°C
- humidity range: 10 to 95 % RH
- display for the values
TH623 specific description
- temperature range: 0 to 50°C, 0 to 85°C (selectable)
- humidity range: 0 to 95 % RH
- display for the values
- alarm
- external probe
TH625 specific description
- temperature range: 0 to 50°C, 0 to 85°C (selectable)
- humidity range: 0 to 95 % RH
- display for the values
- alarm with contact relay
- external probe
commun description
- temperature precision: ±0,5% for the full scale and ±1°C
- humidity precision: ±2% from 10 to 60%, ±3% from 60 to 95%
- respons time: 2.5 minutes
- recording time: 24 hours or 7 days selectable
- ambient operating conditions: 0 to 50°C, 0 to 95 % RH non-condensing
- adapter 220V/9V
- backup with battery
- battery life (average): 24 hours
- disc diameter: about 15 cm
|


|
Recorder TH8
TH800 specific description
- temperature range: 0 to +50°C
- temperature sensor: thermistor
- humidity range: 10 to 95 % RH, non condensing
- recording time: 24 hours or 7 days selectable
- only wit batteries (4 x AA)
- batteries life: 1 week to 12 months depending on the rotation speed
TH801 specific description
- temperature range: 0 to +50°C
- temperature sensor: thermistor
- humidity range: 10 to 95 % RH, non condensing
- recording time: 24 hours or 7 days selectable
TH802 specific description
- temperature range: 0 to +50°C, 5 to +40 °C
- temperature sensor: thermistor
- humidity range: 10 to 95 % RH
- display for the values
- recording time: 24 hours, 7 days or 31 days selectable
TH803 specific description
- temperature range: -20 to 50°C, 5 to +40°C (selectable)
- temperature sensor: thermistor, remote probe
- humidity range: 0 to 95 % RH, remote probe
- display for the values
- audio/ visual alarm
- recording time: 24 hours, 7 days or 31 days selectable
general description
- temperature precision: ±1°C
- humidity precision: ±2% from 0 to 60%, ±3% from 60 to 95%
- dew point range (calculated): -30 °C to 50 °C
- dew point accuracy (calculated): ±4 °C from 10 to 95% RH
- respons time: 2 minutes for 63 % of the full scale
- ambient operating conditions: 0 to 50°C, 0 to 95 % RH non-condensing
- adapter 220V/9V
- backup with battery
- battery life (average): 24 hours
- disc diameter: about 24 cm
|
 |
Datalogger Testo 177-H1
- Temperature range: -20 to +70 °C (internal sensor), -40 to +120 °C (external Sensor)
- Precision: ±0.2 °C (-25 bis +70 °C)
- Resolution: 0.1 °C
- Humidity range: 0 to 100 % rH (capacitiv sensor)
- Resolution: 0.1 % rH
- 4 Channels
- Memory: 48000 poins
- ambient operating conditions: -20 to +70 °C
- Battery: Lithium-Batterie
- Weight 130 g
- Dimension: 103 x 64 x 33 mm
|
 |
Data logger TR-72W

- Incorporate an Ethernet/ LAN interface
- Can be connected to wired or wireless LAN
- One external temperature sensor (with the humidity sensor): 0 to 50 °C
- One external humidity sensor: 10 to 95 % rH
- Measurement Accuracy: ±0.3°C(-20 to 80°C), 5 % rH
- Measurement Resolution Display: 0.1°C, 1 % rH
- Recording Interval 1,2,5,10,15,20,30 seconds,1,2,5,10,15,20,30,60 minutes
- Recording Capacity: 8,000 Readings x 2 Channels
- Recording Method Endless (Overwrite from the oldest data when recording capacity is full), One time Method (Stop recording when recording capacity is full)
- Power Source: Special AC Adaptor ( DC5V )
- Data Back-up: Saved for about 3 months with 1 lithium battery (CR-2032)
- Interface Wired LAN: 10 / 100 Base - TX RJ45 connector
- Wireless LAN:IEEE802.11b CF type Wireless LAN Card
- Dimentions: H55mm x W78mm x D39mm
- Weight 101g ( Including one battery )
- Browser Functions View Temperature and Humidity Data in Graph Form , Start Recording, Download Data , Monitor Current Readings , Check Back-up Battery
- Warning Mail Function E-mail: Register up to 5 addresses to receive mail
- Power Consumption: About 290mA ( when using wired LAN )
- Security Access Controlled IP Address , ID Password Authentication
- Working Environment for Main Unit Temperature : 0 to 50°C Humidity : 20 to 80%RH (without condensation)
|

|
Data logger MSR145
- The MSR 145 is a miniaturised universal datalogger for measuring and recording different physical measurement parameters. It contains a temperature sensor, a humidity sensor with integrated temperature, a pressure sensor and a 3-axis accelerometer (X, Y and Z axes).
- Temperature range: -20 °C to +60 °C
- Humidity range: 0-100 % relative humidity
- Pressure: 0 to 2500 mbar absolute (optional: to 14 000 mbar absolute)
- Acceleration: ±10 g / ±2 g (switchable)
- Accuracy: ±0,5 °C max. (at -10 °C to +60 °C), optional ±0,2 °C max. (at 20 °C to 40 °C), < ±2 % relative humidity (at 10-90 % relative humidity, 0 °C to 40 °C), ±2,5 mbar max. (at 750-1100 mbar absolute), Acceleration: ±0,15 g (at 25 °C)
- Memory: 2 500 000 Values
- Data storage rate:
- for temperature: 1 /s, every 10 s, every 30 s, every 60 s
- for humidity: 1 /s, every 10 s, every 30 s, every 60 s
- for pressure: 20 /s, 10 /s, 2 /s, 1 /s, every 10 s, every 30 s, every 60 s
- for acceleration: 20 /s, 10 /s, 1 /s, every 2 s, every 5 s, every 10 s, every 30 s, every 60 s
- Power supply: Rechargeable lithium polymer battery 188 mAh, the battery is charged via the USB connection, one battery charge is sufficient for operation of the unit for several months (measurement rate 1/minute).
- MSR145 S: for air, size 18 x 14 x 52 mm, weight approx. 13 g, sheath material PVC, IP60
- MS145W: for air and water, size 18 x 14 x 60 mm, weight approx. 18 g, sheath material Silicon, IP68
- Data transfert: with USB connection, software is included
- Different versions with only a few parameters (like temperature and humidity) are also available
|
|

Description

|
Radio data logger Newsteo LOG221
The logger can transfer the data directly on a monitoring computer by radio frequencies or can store the data in its memory.
Up to 500 loggers can communicate with one RF-USB stick connected to the computer.
specification
- temperature range: -40 to 60 °C
- temperature precision: ±0,8 °C at 25 °C
- humidity range: 0 to 100 % RH
- humidity precision: ± 3% RH
- sample interval: 1 second to 1 day
- memory: 32768 points
- min/max value
- battery life: 2 years (for 1 mesurement/10 minutes)
- IP54
- dimension: 96 mm x 40 mm x 20 mm (antenna: 90 mm)
- RF range: 30 m to 1 km (there are different antenna sizes)
applications
- storage control
- transport of fresh, frozen food, pharmaceuticals...
|
 |
Newsteo Builder for measurement of the humidity and shrinkage of concrete
It is directly buried (antenna included) into the concrete and it records the corresponding measurements in its non-erasable embedded memory (which can be at any time read by a PC).
It can also transmit them in real time, without any wire, to a PC. As all the measurements are dated, the user gets the complete history of the supervised concrete.
Two versions of the Newsteo Builder, with or without the shrinkage sensor, are available.
Spécicifications:
- temperature range: -20°C to +124°C
- humidity range: 0 to 100%
- shrinkage range: -300 to 800 µm/m
- working temperature: -20°C to +80°C
- autonomy: 3 to 7 ans with lithium battery (depending on the measurement frequency and the working temperature)
- measurements frequency: every 10 minutes to every 4 hours
- storage capacity: 32768 dated values
- protection: IP 68 (resistant to dust, to liquid concrete, suitable for continuous immersion in water under static pressure of 6 bar)
- dimensions : 67 mm x 73 mm x 29 mm.
- casing in tear-proof and unbreakable polyurethane
- Shrinkage sensor dimensions: 155 mm x 20 mm x 15 mm, connection cable : 40 cm
|
|
|