Data logger PR125/PR325/PR525/PR120/PR320
PR125 specific description
- pressure range: 0 to 100 PSI
PR325 specific description
- pressure range: 0 to 300 PSI
PR525 specific description
- pressure range: 0 to 500 PSI
PR120 specific description
- pressure range: 0 to 100 PSI
- without display
PR320 specific description
- pressure range: 0 to 300 PSI
- without display
commun description
- FLASH card option
- Accuracy: ±1% of full scale
- Ambient Operating Conditions: -30 to +80°C, 0 to 100% RH
- IP Rating: IP68
- Units of Measure: Via DicksonWare: PSI, ATM, Bar, mBar, InH2O, FtH2O, mmH2O, mmHG, InHg, Pascal, kP, MCA
- Via Display: PSI, ATM, mBar, InH2O, kP, MCA, BAR
- Approvals: CE
- Battery Type: 1 DL123 Lithium Battery (User Replaceable)
- Battery Life: 6 months at 5 Minute Sample Rate
- Fitting: 1/4'' NPT Thread, 5/8'' Hex
- Sample Point Storage: 60,000 points
- Sample Interval: User selectable from 1 second to 24 hours
- Download Time: Approximately 1 minute with logger full
- Download Type: USB or Flash Memory Card
- Enclosure: Glass filled Polycarbonate; Stainless Steel Hex
- Dimensions: 8.64cm DIA x 7.11cm H
- Weight: 300 g
- software for data transfert: ref. A016 (RS232), and SW400 for calibration
|
PW8
|
Chart recorder PW8
PW861 specific description
- pressure range: 0 à 100 PSI
- recording time: 24 hours
PW860 specific description
- pressure range: 0 à 100 PSI
- recording time: 7 days
PW865 specific description
- pressure range: 0 à 200 PSI
- recording time: 24 hours
PW864 specific description
- pressure range: 0 à 200 PSI
- recording time: 7 days
PW867 specific description
- pressure range: 0 à 300 PSI
- recording time: 24 hours
PW866 specific description
- pressure range: 0 à 300 PSI
- recording time: 7 days
PW875 specific description
- pressure range: 0 à 1000 PSI
- recording time: 24 hours
commun description
- pressure accurancy: ±2 % full scale
- respons time: 5 seconds
- IP 66
- ambient operating conditions: -30 to +50°C, 0 to 95 % RH
- one AA battery included
- battery life (average): 1 year
- disc diameter: about 24 cm
|
PW4
|
Chart recorder PW4
PW450 specific description
- pressure range: 0 to 100 PSI
- recording time: 7 days
PW451 specific description
- pressure range: 0 to 100 PSI
- recording time: 24 hours
PW452 specific description
- pressure range: 0 to 150 PSI
- recording time: 7 days
PW453 specific description
- pressure range: 0 to 150 PSI
- recording time: 24 hours
PW454 specific description
- pressure range: 0 to 200 PSI
- recording time: 7 days
PW455 specific description
- pressure range: 0 to 200 PSI
- recording time: 24 hours
PW456 specific description
- pressure range: 0 to 300 PSI
- recording time: 7 days
PW457 specific description
- pressure range: 0 to 300 PSI
- recording time: 24 hours
PW458 specific description
- pressure range: 0 to 500 PSI
- recording time: 7 days
PW459 specific description
- pressure range: 0 to 500 PSI
- recording time: 24 hours
PW461 specific description
- stainless steel sensor
- pressure range: 0 to 300 PSI
- recording time: 7 days
PW462 specific description
- stainless steel sensor
- pressure range: 0 to 600 PSI
- recording time: 7 days
commun description
- pressure accurancy: ±2 % full scale
- respons time: 1 second
- ambient operating conditions: -30 to +50°C
- one AA battery included
- battery life (average): 1 year
- disc diameter: about 12 cm
|