Infrared Temperature Indicator Testo 805
- non contact thermometer
- temperature range: -25 to +250 °C
- precision: ± 2 %
- ambient operating conditions: 0-50°C, 35 to 85 % RH
- without laser pointer
|
 |
Infrared Temperature Indicator Testo 826-T2
- non contact thermometer
- temperature range: -50 °C to 300 °C
- precision: ± 2 %
- laser sighting: single point
- ambient operating conditions: 0-50°C, 35 to 85 % RH
- resolution: 0.5 °C
|
 |
Infrared Temperature Indicator Fluke 62
- non contact thermometer
- temperature range: -30 °C to 500 °C
- precision: ± 2 %
- very short respons time (500 msec for 95 % of the respons)
- field of view: 10:1
- pre-seted emissivity: 0.95
- laser sighting: single point
- ambient operating conditions: 0-50°C, 35 to 85 % RH
- 9 V battery
|
 |
Infrared Temperature Indicator Fluke FoodPro
- specially designed for food products
- temperature range: -30°C to 200 °C
- precision: ±1 °C or 1.5 %
- field of view: 2.5:1
- pre-seted emissivity: 0.97
- ambient operating conditions 0-50°C, 35 to 85 % RH
- IP54
- 9 V battery
- ideal for HACCP norms
|
 |
Infrared Temperature Indicator Fluke FoodPro Plus
- specially designed for food products
- combines and infrared thermometer with a built in probe thermometer
- temperature range: -30°C to 275 °C
- precision: ±1 °C or 1.5 %
- field of view: 2.5:1
- temperature range for probe: -40 °C to 200 °C
- precision for temperature probe: 1 °C
- pre-seted emissivity: 0.97
- measured surface visualised with LED
- ambient operating conditions 0-50°C, 35 to 85 % RH
- IP54
- 9 V battery
- ideal for HACCP norms
|
 |
Infrared Temperature Indicator Fluke 561
- non contact thermometer
- temperature range: -40 °C to 550 °C
- precision: ± 1 % or 1 °C (the highest value)
- very short respons time (500 msec for 95 % of the respons)
- field of view: 12:1
- 3 pre-seted emissivities: low (0.3), medium (0.7), high (0.95)
- laser sighting: single point
- ambient operating conditions: 0-50°C, 35 to 85 % RH
- with external type K sensor included
- LCD with 2 values: actual value and MAX/MIN/DIF/RTC
- 2 x AA batteries
|
 |
Infrared Temperature Indicator Fluke 566
- non contact thermometer
- temperature range: -40°C to 650 °C
- precision: ± 1°C or 1 %
- field of view: 30:1
- adjustable emissivity
- laser sighting: single point
- max, min, dif and avg temperature display
- memory for 20 values
- connection for thermoelement type K (one included)
- ambient operating conditions 0-50°C, 35 to 85 % RH
- 9 V battery and case included
|
 |
Infrared Temperature Indicator Fluke 568
- non contact thermometer
- temperature range: -40°C to 800 °C
- precision: ±1°C or 1%
- field of view: 50:1
- adjustable emissivity
- laser sighting: single point
- max, min, dif and avg temperature display
- memory for 99 values
- connection for thermoelement type K (one included)
- USB for connection to a PC, software included
- ambient operating conditions 0-50°C, 35 to 85 % RH
- 9 V battery and case included
|
 |
Infrared Temperature Indicator Fluke 572
- non contact thermometer
- temperature range: -30°C to 900 °C
- precision: 0.75 % or ±2%
- very short respons time 250 msec for 95 % of the respons)
- field of view: 60:1
- adjustable emissivity
- laser sighting: measured surface (3 points)
- ambient operating conditions 0-50°C, 35 à 85 % RH
- 9 V battery
- included: box, 2 batteries
|
 |
Infrared Temperature Indicator Fluke 574
- non contact thermometer
- temperature range: -30°C to 900 °C
- precision: 0.75 % or ±2%
- very short respons time 250 msec for 95 % of the respons)
- field of view: 60:1
- adjustable emissivity
- laser sighting: measured surface (3 points)
- memory for 100 data points
- with the included software (for RS232 port), the temperature measurement can be displayed directly on the computer screen
- ambient operating conditions 0-50°C, 35 à 85 % RH
- 9 V battery
- included: box, 2 batteries, software, thermoelement type K, RS232 cable
|
 |
Infrared Temperature Indicator Fluke 576
- like Fluke 574 but with digital photo camera and USB connector
|
 |
Infrared Temperature Indicator Testo 830-T2
- temperature range: -30 to +400 °C
- precision: ±1.5 °C or ±1.5% of mv (+0.1 to +400 °C) ±2 °C or ±2% of mv (-30 to 0 °C)
- 12:1 optics for larger surfaces
- 2-point laser sighting
- display of actual value and Hold value
- audible and optical alarm when limit values are exceeded
- fast measurement value recording at 2 measurements per second
- display illumination
- emissivity determination with external TC probe
- 2 laser beams for sighting
- contact measurement with connectable temperature probe
- Ref. 0560 8302 IR thermometer alone, Ref. 0563 8302 external contact thermometer is included
|
 |
Infrared Temperature Indicator Testo 830-T3
- temperature range: -30 to +400 °C
- precision: ±1 °C (-20 to +100 °C) ±2 °C or ±2% of mv (remaining range)
- small measurement point of 2 mm, distance 25 mm
- °C contact measurement with attachable TC probe
- backlit display
- audible and optical alarm when limit values are exceeded
- emissivity adjustable 0.2 to 1.0
- 2 point laser sighting
- fast measurement value recording at 2 measurements per second
- current value and Hold value
- ref. 0560 8303 IR thermometer alone
|
 |
Infrared Temperature Indicator Testo 830-T4
- infrared temperature range: -30 à +400 °C
- with external type K thermoelement
- external temperature range: -50 to +500 °C
- precision: ±1,5 °C (-20 to 0 °C), ±2 °C (-30 to -20,1 °C), ±1 °C or 1% mv (remaining range)
- optic: 30:1
- measurement point of 32 mm at 1 m
- backlit display
- audible and optical alarm when limit values are exceeded
- emissivity adjustable 0.2 to 1.0
- 2 point laser sighting
- fast measurement value recording at 2 measurements per second
- current value and Hold value
- ref. 0563 8304 external thermometer included, ref. 0560 8304 without external thermometer
|
 |
Infrared Temperature Indicator Testo 845
- non contact thermometer
- infrared temperature measuring instrument with cross laser marking and switchable optics for far-field and close focus measurement, incl. PC software with USB data transfer cable, aluminium case, battery and calibration protocol
- measurements in the far-field are made with an optical resolution of 75:1. Surface temperatures can thus be measured accurately even at greater distances from the object to be measured. At a distance of 1.2 meters from the object, the measurement point diameter is only 16 mm. A cross laser marks the measurement point exactly.
- for measurements at a small distance from the object to be measured, the close focus optics provide a measurement point diameter of only 1 mm at a distance of 70 mm. Two laser points mark the measurement point.
- reference accuracy ± 0.75 °C with super-fast measurement technololgy (scanning 100 ms)
- optical and audible alarm when limit values are exceeded
- probe socket for TC probes for determining emissivity
- temperature range for IR and thermocouple type K: -35 ... +950 °C
- precision IR: ±2.5 °C (-35 to -20.1 °C), ±1.5 °C (-20 to +19.9 °C), ±0.75 °C (+20 to +99.9 °C), ±0.75% of mv (+100 to +950 °C)
- resolution 0.1 °C
- operating temperature: -20 to +50 °C
- battery type 2 AA batteries
- weight 465 g, dimensions 155 x 58 x 195 mm
- memory for 90 measurement protocols (date, time, IR °C, td °C , external probe temperature, ...)
- PC software for archiving and documenting measurement data (included in delivery)
- tripod fitting for online measurement via USB cable (included in delivery)
- measurement data documentation on site with testo report printer
- aluminium case for instrument and accessories (included)
|
 |
Infrared Temperature Indicator Testo 845/humidity
- like the Testo 845 but with Integrated humidity module for measuring indoor air humidity and for determining dewpoint distance
- humidity range: 0 ... +100 %HR
- precision: ±2 %HR (2 ... 98 %HR)
|
 |
Infrared Temperature Indicator Raytek 3i
- temperature range: -30 bis 1200°C
- spectrum: 8 to 14 µm
- emissivity: 0,10 - 1,0 (in 0,01 steps)
- battery: 4 x 1,5 V Typ R6 (AA) batteries or 6-9 V, 200 mA adapter
|
 |
Thermal imager (infrared) Fluke Ti10
- temperarure range: -20 to 250°C,
- Sensortype 160 x 120 Pixel
- Easy to use, thanks to one-handed "point-and-shoot" operation and intuitive on-screen guidance
- does not require specialist training to obtain accurate measurements
- how it works: point at the target, focus the instrument, it automatically adjusts the temperature range to show a crisp image. When the user pulls the trigger, the image and associated measurement data is stored. Through the software (InsideIR, included), key image parameters can be changed to optimize the image and extract maximum detail without going back to the factory floor.
|
 |
Thermal imager (infrared) Fluke Ti20
- temperarure range: -20 to 350°C
- Sensortype 128 x 96 Pixel
- Easy to use, thanks to one-handed "point-and-shoot" operation and intuitive on-screen guidance
- does not require specialist training to obtain accurate measurements
- how it works: point at the target, focus the instrument, it automatically adjusts the temperature range to show a crisp image. When the user pulls the trigger, the image and associated measurement data is stored. Through the software (InsideIR, included), key image parameters can be changed to optimize the image and extract maximum detail without going back to the factory floor.
|
 |
Thermal imager (infrared) Testo 875-1
Thermal imager with a temperature resolution of <80mK and useful analysis functions for a professional start in thermography.
- Detector type 160 x 120 pixels
- Good image quality NETD <<80 mK
- High quality standard lens 32° x 23°
- Auto Hot/Cold Spot Recognition
- Manual focus
- Temperature range -20 to +280°C
Incl. in delivery:
- Pro software with integrated report creation
- SD card
- USB cable
- Mains uni
- Li-ion rechargeable battery
- Adapter for tripod mounting
- Robust, high-quality case
|
 |
Infrared Temperature Indicator CM Serie
- non contact thermometer
- temperature range: -20 to 500 °C
- standard J or K thermoelement output or 0-5 V
- alarm output
- rugged IP 65 stainless steel housing
- function in ambient temperatures to 70°C without cooling
- 13:1 optics at 90% energy
- 150 mSec (95 %) response time
- powered by 12-24 VDC at 20 mA
- accessories available for cooling
- emissivity: 0.1 to 1.1
- RS232 interface for configuration with DataTemp® Multidrop Software
|
 |
Infrared Temperature Indicator MID Serie
- non contact thermometer
- small sensing head fits where other sensors can’t
- ambient head temperatures up to 180°C without cooling
- industrial rugged head cable: Silicone and Halogen free, resistant against oil, bases, and acids (MID/MIC)
- 1% accuracy across broad temperature range
- 0/4 20 mA, 0 5 V, J or K thermocouple output
- interchangeable sensing heads
- adjustable emissivity, transmissivity, peak hold, valley hold and averaging
- 5-digit backlit LCD user interface
- accessories for mounting and air purging
- interface: RS232 (standard) or RS485 (optional)
- multidrop Network (max. 32 sensors with RS485)
|
 |
Infrared Temperature Indicator TX Serie
- non contact thermometer
- simple, two-wire installation
- simultaneous 4-20 mA and digital output for smart TX sensors
- compact, rugged sensor with IP 65 rating
- wide temperature range from -18 to 2000°C
- advanced signal processing
- point-to-point or multidrop installation
- install up to 15 sensors on a single multidrop network
- windows software for remote configuration and monitoring
- wide choice of focus distances
- special models for glass and plastics applications
|
 |
Infrared Temperature Marathon MM Serie
- non contact thermometer
- wide temperature range from -40°C to 2250°C
- optical resolution up to 70:1
- spot sizes down to 1,1 mm
- variable focus from 0,2 m to 2,2 m
- fast response time down to 20 ms
- real time video monitoring and recording capability
- through-the-lens sighting with video or laser aiming
- digital RS485 communications (networkable)
- real time ambient background radiation compensation
- simultaneous analogue and digital outputs
- programmable relay output
- ambient temperatures to 315°C with ThermoJacket
- compact, rugged design, IP65 rated
- dataTemp® Multidrop software for remote configuration
|